Université Blida 1

L’évaLuation TOXICOLOGIQUE de L’incidence de L’irritation par Les produits dermocosmétiques « Réalisation du test Het-Cam »

Afficher la notice abrégée

dc.contributor.author BOUZERIDA, Zoubida
dc.contributor.author LAGHROUR, Halima Ghada
dc.contributor.author RAHMANI, L. (promotrice)
dc.contributor.author MAMMERI, K. (promotrice)
dc.date.accessioned 2024-03-25T10:22:51Z
dc.date.available 2024-03-25T10:22:51Z
dc.date.issued 2022
dc.identifier.uri https://di.univ-blida.dz/jspui/handle/123456789/28662
dc.description MPHA 531 fr_FR
dc.description.abstract L’objectif principal de notre étude est l’évaluation toxicologique des produits dermocosmétiques en se basant sur la réalisation du test HET-CAM et le traitement des données collectées via un questionnaire (160 sujets). Pour le test HET-CAM qui est une méthode alternative au test de draize oculaire ; élaboré pour l’évaluation de l’irritation et/ou la corrosion oculaire, son principe en est basé sur l'observation des effets irritants (hyperémie, hémorragie, coagulation) pouvant survenir dans les cinq minutes suivant le dépôt d'un produit sur la membrane chorio-allantoïdienne d'œuf de poule embryonné, au dixième jour d'incubation. On a testé 24 produits ; Parmi lesquelles, des réactions positives ont été enregistrées pour 05 produits soit 20.83% : Parmi les 05 produits ; 2 sont des écrans solaires de marques différentes ; et 3 produits antiseptiques. ème Pour la 2 partie pratique ; un questionnaire a été adressé à une population d’étude de 160 femmes dans la région de BLIDA sur une période allant du 8 janvier 2022 au 10 janvier 2022 à travers un lien électronique vue la situation sanitaire actuelle de la pandémie. On a constaté que 25 personnes soit 15.62% ont eu des effets indésirables suite à l’utilisation de produits dermocosmétiques. Abstract : The main objective of our study is the toxicological evaluation of dermocosmetic products based on the performance of the HET-CAM test and the processing of the data collected via a questionnaire (160 subjects). For the Het-Cam test which is an alternative method to the eye balance test ; developed for the evaluation of eye irritation and/or corrosion, its principle is based on the observation of irritant effects (hyperemia, hemorrhage, coagulation) may occur within five minutes of depositing a product on the chorio-allantoic membrane of an embryonic hen egg on the tenth day of incubation. We tested 24 products ; among which, positive reactions were recorded for 05 products or 20.83% : Among the 05 products ; 2 are sunscreens of different brands ; and 3 antiseptic products. For the second practical part, a questionnaire was sent to a study population of 160 women in the BLIDA region over a period from 8 January 2022 to 10 January 2022 through an electronic link given the current health situation of the pandemic. It was found that 25 people or 15.62% had adverse effects following the use of dermocosmetic products. fr_FR
dc.language.iso fr fr_FR
dc.publisher Université de Blida 1, Faculté de Medecine fr_FR
dc.subject Cosmétiques / test in vitro / Dermocosmétique / Irritation / HET-CAM / toxicité fr_FR
dc.subject Dermocosmetic / irritation / HET-CAM / toxicity / test in vitro / cosmetics fr_FR
dc.title L’évaLuation TOXICOLOGIQUE de L’incidence de L’irritation par Les produits dermocosmétiques « Réalisation du test Het-Cam » fr_FR
dc.type Thesis fr_FR


Fichier(s) constituant ce document

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée

Chercher dans le dépôt


Recherche avancée

Parcourir

Mon compte